For most construction perimeters, the real choice sits between aluminium composite (ACM/dibond) for branded, longer-term sites, steel panels where security is the priority, plywood or timber for short, budget-driven jobs, and rigid PVC or recycled plastic where weather resistance matters most. Before ordering, always confirm fire classification, panel support design and any local height rules that apply to your site.
TL;DR:
- Steel panels are ideal for high-security sites and city-centre projects, typically exceeding 2 meters in height and requiring lockable fixings.
- ACM or dibond panels are suited for brands and long-term use, with thicknesses between 3mm and 6mm to balance rigidity and wind resistance.
- Plywood should be pressure-treated, kiln-dried, and supported by reliable fire classification documentation, as marketing claims are often unverified.
- Panel support must be tailored to wind load conditions, with steel posts preferred for extended durations and proper fixings to prevent loosening or collapse.
- Proper sealing of joints, accurate panel sizing, and thorough documentation of fire safety certificates are critical for safe, durable, and compliant hoarding systems.
Table of Contents
- 1. Common hoarding panel materials and when to use them
- 2. Technical specifications and safety: thickness, fixings, wind loading and fire performance
- 3. Standard sizes, panel layout and installation considerations
- 4. How to choose: matching material to the project
- 5. Printing, finishes and branding options for hoardings
- 6. Maintenance, inspection and compliance during the contract
- 7. What specification mistakes come up again and again
- Specification support and printed hoarding production
- FAQ
- Sources
1. Common hoarding panel materials and when to use them
Aluminium composite panels, known in the trade as ACM or dibond, consist of a polyethylene core sandwiched between two thin aluminium skins. They print cleanly, resist warping better than timber, and typically come in thicknesses between 3mm and 6mm, which makes them a strong fit for branded hoardings that need to look sharp for months at a time.
Steel hoarding panels suit sites where security outranks presentation. Modular steel systems lock together, resist forced entry better than lightweight boards, and are commonly specified at 2.0m to 2.4m heights on higher-risk or city-centre sites.
Plywood and timber remain the cheapest starting point, but they come with real limitations: standard construction ply swells and delaminates if water gets behind the printed face, and untreated boards weather quickly. Where timber is used, it should be pressure-treated and kiln-dried to reduce moisture uptake.
Rigid PVC, foamex and recycled plastic boards offer a lighter, weatherproof alternative that resists rot entirely, though they flex more under wind load than ACM or steel.
A word of caution on fire-retardant plywood: marketing claims around Euroclass ratings are not always reliable. An OPSS product safety report found plywood sold as Euroclass B that did not reliably meet that declared performance, so a certificate on a datasheet is not proof on its own.
- ACM/dibond: best for branding and mid-to-long-term sites, 3-6mm thickness.
- Steel panels: best for high-security or city-centre sites, typically 2.0-2.4m high.
- Plywood/timber: lowest upfront cost, shortest service life, needs treatment.
- PVC/recycled plastic: weatherproof and rot-free, more flexible under wind load.
2. Technical specifications and safety: thickness, fixings, wind loading and fire performance
Thickness drives stiffness far more than most procurement teams expect. A thin board that looks fine on the ground can flex and drum in wind, loosening fixings over weeks rather than days. As a rough guide, ACM typically runs 3-6mm, structural plywood for hoarding is commonly specified from 12mm upwards, and steel panel gauges vary by manufacturer, so always ask for the spec sheet rather than assuming equivalence between suppliers.

Support systems matter as much as the panel itself. Timber posts are cheaper and easier to source but weather faster than steel, and SGG11C recommends steel posts in preference to timber where a hoarding will remain in place for extended durations. The Temporary Works Forum treats hoarding design as a temporary works discipline in its own right, requiring an independent check because wind loading and shielding from nearby tall buildings have caused real collapses when ignored.
Fire performance should never be taken on trust. Ask every supplier for the Euroclass or UKCA classification plus the underlying test report and Declaration of Performance, not just a product sheet claim.
- Request the Declaration of Performance (DoP) and UKCA marking documentation before delivery.
- Confirm the specific test report number matches the Euroclass rating claimed.
- Check post spacing and foundation detail against the manufacturer’s structural guidance.
- Record panel batch numbers on arrival for traceability if a defect emerges later.
Pro Tip: Keep every DoP and test certificate in the project file from day one. Chasing paperwork after a fire inspector asks for it is far harder than filing it on delivery.
3. Standard sizes, panel layout and installation considerations
Hoarding height is driven by context more than preference. HSE guidance notes that a two-metre fence works for most sites, but larger hoardings are often needed in city-centre or residential areas, and perimeter designs must prevent climbing and close off gaps underneath or between panels.
ACM, plywood and PVC panels are typically supplied in sheet sizes that suit 2.0m and 2.4m post centres, keeping joints consistent and minimising cut waste. Overlaps and vertical joints need careful detailing: a poorly sealed joint is the most common point of water ingress on branded hoardings.
- Specify panel heights of 2.0m to 2.4m depending on site context and local requirements.
- Maintain clear pedestrian sightlines and footway setbacks at every junction and crossing point.
- Include lighting at access points and any section with reduced natural light.
- Seal vertical joints with foil tape and use flash bands at panel tops to stop water tracking behind the face.
4. How to choose: matching material to the project
The right material depends on which priority wins: security, branding, speed, budget or sustainability. Getting this sequence backwards, choosing the cheapest board first and retrofitting security or branding later, is where most procurement headaches start.
- Security-led sites: specify steel panels with through-bolted fixings and locked sectional joints.
- Branding-led sites: specify ACM/dibond for print quality and panel rigidity over the contract term.
- Short-term or low-budget jobs: plywood can work, provided it is pressure-treated and the contract accepts a shorter service life.
- Sustainability-led briefs: look at recycled plastic boards and ask suppliers directly about end-of-life recyclability.
- Exposed or complex sites: request an independent structural check per TWf guidance rather than relying on a standard post spacing table.
Common pitfalls worth flagging before signing off a purchase order: accepting a fire rating without the test report behind it, underspecifying post gauge or spacing for the site’s wind exposure, and failing to agree an inspection cadence in the contract itself.
5. Printing, finishes and branding options for hoardings
Direct printing onto ACM gives the sharpest colour and the longest visual life, because the ink sits on a rigid, stable substrate rather than a board that can flex or swell. Printed vinyl applied to plywood or PVC costs less upfront but fades and lifts sooner, particularly at joints and edges exposed to rain.
Anti-graffiti laminates and UV-protective coatings extend legibility at distance, which matters most on fast-moving roads where a hoarding has only seconds to register with a driver or pedestrian.
- Plan artwork layout across panel joins before print, not after, to avoid awkward splits through logos or text.
- Specify an anti-graffiti laminate on any hoarding facing a public footway.
- Ask about recycled or lower-impact substrate options if sustainability is part of the brief.
Pro Tip: Send exact panel dimensions and post centres to your print supplier before artwork is finalised. A design that looks perfect on screen can land awkwardly across real joints if the layout wasn’t checked against the physical panel grid first.
6. Maintenance, inspection and compliance during the contract
A hoarding is not a fit-and-forget asset. SGG11C sets out inspection detail suited to long-duration assemblies, and the same discipline pays off on shorter contracts too.
- Carry out monthly visual checks of fixings, post bases and coating condition.
- Run a six-monthly structural inspection on any hoarding expected to remain for an extended period.
- Record damaged, tampered or loose panels immediately and schedule repair before the next scheduled walk-round.
- Keep photographic inspection records and name a responsible party in the contract, so a principal contractor or local authority query can be answered without delay.
7. What specification mistakes come up again and again
Working across in-house manufacturing on large-format print and hoarding jobs, we see the same specification gaps repeat: post spacing copied from a previous job without checking wind exposure, fire ratings quoted from a brochure rather than a test certificate, and artwork sent for print before final panel counts are confirmed. Bringing a signage supplier in early, while post centres and panel sizes are still being finalised, avoids nearly all of it.
— Steve
Specification support and printed hoarding production
We produce printed hoardings, which helps maintain control over colour accuracy, panel tolerances and turnaround compared to a multi-stage supply chain. Whether your priority is a branded ACM run for a city-centre site or a sustainable substrate for a shorter contract, we work from your post centres and panel grid rather than a generic template.

- Request a specification review before artwork is finalised, so panel joins and post spacing are agreed upfront.
- Ask about sustainable print and substrate options if that is part of your brief.
- Get a quote for printed hoarding production through our signage team.
FAQ
What materials are commonly used for construction hoardings?
The most common substrates are aluminium composite (ACM/dibond), steel panels, plywood or timber, and rigid PVC or recycled plastic. The right choice depends on whether security, branding, budget or sustainability is the priority for that particular site.
What ply to use for hoarding?
Where plywood is used, it should be pressure-treated and kiln-dried to resist moisture, and any fire-retardant claim should be backed by a test report rather than taken from a datasheet alone. Government analysis of timber performance notes that configuration and ageing affect how timber behaves, and that treatments reduce hazard without guaranteeing long-term durability.
What are the standard sizes of hoarding panels?
Hoarding heights are commonly specified at 2.0m or 2.4m, with HSE guidance noting that a two-metre fence suits most sites while larger hoardings often suit city-centre or residential locations. Panel widths typically follow standard sheet sizes to match post centres and minimise cutting waste.
What is a hoarding panel?
A hoarding panel is a section of fencing, usually fixed between posts, used to secure a construction site perimeter and often printed with branding or site information. Panels are chosen based on the substrate, whether ACM, steel, plywood or PVC, that best matches the site’s security, durability and visual requirements.
Sources
- TWf – Hoardings: a guide to good practice
- HSE – Protecting the public (HSG151)
- SGG11C – Specification for the procurement of hoarding
- OPSS product safety report — PAGED BirchPly FR plywood
- Gov